Control Unit
| Power Supply |
96-256VAC 50/60Hz |
| Dimensions |
Standard: (W) 260 mm x (L) 205 mm x (H) 45 mm |
| Control Options |
Illumination, white balance |
| Video Outputs |
Composite VBS, S-VHS (Y/C) out, NTSC or PAL (depends on camera) |
| Options |
Digital output for INVIZ LCD image recorder |
| Other |
19" version available The CCU suppotrs only DE 2.4 / 4.0 cameras |
Video Endoscope Camera INVIZ DE 2.4
| Video |
PAL video 380 TV lines / 290.000 pixel |
| Optic |
100° FOV Standard optics, 3 mm to 200 mm fixfocus. optional: 60° Teleoptic (not changable). |
| Recommended Usage Instructions |
Using with 14” CRT monitor, 100° FOV: 10x / 20 mm distance |
| Illumination |
2 high performance white light LEDs optional: Fiber and LED illuminaton for the enhancement of luminous intensity |
| Dimensions |
Width: 2.40 mm (± 0.03 mm), other versions are available on customers request |
| Water Resistance |
0,1 bar / 1,45 psi |
Video Endoscope Camera INVIZ DE 4.0
| Video |
PAL video 470 TV lines / 440.000 pixel (H752xV582) |
| Optic |
Adjustable focus, 60° FOV, 3 mm to infinite, typical working range 8 mm to 100 mm. Viewing direction adjustable by ± 30°. |
| Recommended Usage Instructions |
Using with 14” CRT monitor, 60° FOV: 18x / 20 mm distance |
| Illumination |
Identic DE 2.4 version, no fiber illumination possible |
| Dimensions |
Width: 4.0 mm (± 0.05 mm), Other versions are available on customers request |
| Water Resistance |
0.5 bar / 7.5 psi |
| Other |
2.1 mm drilling for the use of external parts recovery tools |
Probe
| Working length |
Standard 2 meter, extension up to 5 meter possible |
| Lead |
2.5 meter PU coated, extension up to max. 10 meter (DE 2.4) or 15 meter (DE 4.0) complete length possible |
| Driving Belt |
Open and flexible installation band with regular rectangular recesses for a reliable feed through a (not included) motor drive unit. Through the optimal fiber glass epoxy reinforcement in the inner of a belt , there is a safer and simple operation ensured without manipulator and without kinking during the operation. |
Environmental Conditions / Memory
| Operating Conditions of Camera |
-25°C to 65°C LED head | -25°C to 80°C without LED |
| Operating conditions of control unit |
-20°C bis 45°C |
| Gamma / Neutrons - strength |
This value is not specified due to the partly large lifetime deviations. The value is within the average of semiconductor. |
All specifications are subject to change without notice due to technical progress.